Infographic Edge Facilities
  • More

    Dust Sensor

    Dust sensor
    When dust accumulates into equipment, power usage increases due to the harder working fans and CPU's running at higher temperatures. The Dust Sensor monitors dust particles in the air.

    Dust Sensor

    Close
  • More

    Power Quality Monitoring

    Dust sensor
    The quality of power is one of the main reasons causing equipment to fail, data to be lost or shortening life span of electronics. All impacting business operations. This sensor is able to detect up to 85% of all power quality issues. Plug & Play. No electrical work needed.

    Power Quality Sensor

    Close
  • More

    IO Dry Contact

    Dust sensor
    The dry contact input units enable you to hook up legacy equipment like generators, analog systems or other dry contact systems.

    IO Dry Contact Sensor

    Close
  • More

    Temperature & Humidity Monitoring

    Dust sensor
    The ambient temperature measurement checks if your cooling is still operating and if the room has the desired temperature setting. Combined with the humidity sensors, it ensures that your equipment is running within limits.

    Temperature & Humidity Sensors

    Close
  • More

    Airflow

    Dust sensor
    The airflow sensor monitors the operation of your air ventilation of your Edge facility: for the operation of the intake and outtake vents.

    Airflow Sensor

    Close
  • More

    Battery Monitoring System

    Dust sensor
    The battery monitoring system monitors the temperature, resistance and voltage of your cells. The string is monitored for its current and impedance.

    Battery Monitoring Sensor

    Close
  • More

    Water Leak & Ingress

    Dust sensor
    Water is the enemy of electricity. Inside remote offices or IDF rooms, water leak came come from multiple sources. The primary source is a leaking cooling unit. Then you have water leaks from tenants or rooms above your IDF room, street flooding, pipe bursts and many more. The leak sensor by ServersCheck is a 6m water leak sensitive cable so that it can detect water intrusion anywhere in the IDF or office room.

    Water Sensing Sensor & Cable

    Close
  • More

    Thermal Camera Sensors

    Dust sensor
    Thermal runaways of equipment will go undetected with traditional temperature sensors as air conditioning units will try to compensate the heat problem. The thermal camera sensor looks at the equipment and monitors its surface temperature in 4800 points, every 2 seconds.

    Thermal Camera Sensor

    Close
  • More

    PM Particle Sensor

    Dust sensor
    Dust accumulation in equipment will affect the reliability of systems. At first power usage will increase due to the harder working fans and CPU. Electrical issues may occur due to shortage caused by particles.

    Particle Matter Sensor

    Close
  • More

    Power Failure

    Dust sensor
    Power failure is a common reason why edge facilities go offline. Too often the PDU's do not have the built-in alerting capabilities like with LTE or Satellite connectivity. This sensor ensures that you know when there is an AC power failure so that you can take action before it's too late.

    Power Failure Sensor

    Close
  • More

    CO2 & VOC gas sensors

    Dust sensor
    Li-ion fires are preceded by gas venting of battery cells. Typically this stage gives a few minutes warning before batteries produce smoke and the fire starts. The gas being monitored for Li-ion is CO2.

    CO2, VOC & Temperature Sensor

    Close
  • More

    Corrosive Gas Sensors

    Dust sensor
    Corrosive gasses may be present in the outdoor air. Through ventilation they may get into your facility. H2S & SO2 gasses are known to corrode electrical and electronic equipment resulting in an environmental risk for your facilitiy. NOx & VOC form another danger to your facility.

    Corrosive Gas Sensing

    Close
  • More

    Refrigerant Gas Leaks

    Dust sensor
    Refrigerants are often used in Edge facilities. Using our R-gas sensor, leaks can be detected to mitigate the risk from a failing refrigeration and cooling system.

    Refrigerant Gas Sensors

    Close
  • More

    Daisy Chain Temperature & Humidity Sensors

    Dust sensor
    ASHRAE recommends 6 temperature sensors per rack. Others like Gartner recommend a minimum of 3 temperature sensors per rack: 2 on the intake side (top & bottom) and 1 one at the top back (outtake).

    The daisy chain temperature (humidity) sensors are designed to solve the limitations of standalone sensors

    Daisy Chain Temperature Sensor

    Close
  • More

    Grounding / Earthing Sensor

    Dust sensor
    This sensors checks non stop the grounding's resistance. This allows you to get early warning on your grounding system.

    The sensor detects following:
    - accidental disconnected grounding systems
    - corrosion of copper ground bars due to environmental conditions
    - copper ground theft

    Earthing / Grounding Sensor

    Close
non-relevant transparent gif
Modular edge data center monitoring
with InfraSensing's sensors
Using sensors to monitor edge containerized data centers can provide several benefits, including:

Temperature sensors: These sensors can be used to monitor the temperature in the container and alert maintenance staff if it exceeds a certain threshold. The benefit of using temperature sensors is to ensure that the temperature in the container is within an acceptable range, as extreme temperatures can cause equipment to fail or become damaged.

Humidity sensors: These sensors can be used to monitor the humidity in the container and alert maintenance staff if it falls outside of an acceptable range. The benefit of using humidity sensors is to ensure that the humidity in the container is within an acceptable range, as high humidity can cause equipment to corrode or malfunction, while low humidity can cause static electricity and damage electronic components.

Airflow sensors: These sensors can be used to monitor the airflow in the container and alert maintenance staff if it falls outside of an acceptable range. The benefit of using airflow sensors is to ensure that there is adequate ventilation in the container, as poor airflow can cause equipment to overheat and malfunction.

Dust sensors: These sensors can be used to detect the presence of dust in the container and alert maintenance staff if it exceeds a certain level. The benefit of using dust sensors is to ensure that the container is kept clean, as dust can clog filters, obstruct airflow, and cause equipment to malfunction.

Atmospheric corrosion & corrosive gases sensors: These sensors can be used to detect corrosion or corrosive gases in the container and alert maintenance staff if either is detected. The benefit of using these sensors is to identify corrosion or corrosive gases early, before they cause significant damage, and take preventive action to extend the life of equipment.

Smoke/fire sensors: These sensors can be used to detect smoke or fire in the container and alert maintenance staff if either is detected. The benefit of using smoke/fire sensors is to ensure the safety of the container by detecting fires early and alerting maintenance staff to take corrective action.

Water leak sensors: These sensors can be used to detect water leaks and alert maintenance staff if any are detected. The benefit of using water leak sensors is to prevent water damage to equipment and the container itself, as water can cause serious damage if left unchecked.

Vibration sensors: These sensors can be used to detect vibration and alert maintenance staff if any unusual vibration is detected. The benefit of using vibration sensors is to identify potential problems with equipment, such as imbalanced loads or misalignment, and take corrective action before the equipment fails.

Power quality sensors: These sensors can be used to monitor the quality of the electrical power in the container and alert maintenance staff if any issues are detected, such as voltage spikes or sags. The benefit of using power quality sensors is to ensure that the electrical power in the container is stable and of high quality, as poor power quality can cause equipment to malfunction or fail.

Earthing sensors: These sensors can be used to monitor the earthing system in the container and alert maintenance staff if there are any issues with the earthing. The benefit of using earthing sensors is to ensure that the earthing system is functioning properly and safely, as a faulty earthing system can cause electrical shocks or equipment damage.

Refrigerant leak sensors: These sensors can be used to detect refrigerant leaks in the container and alert maintenance staff if any are detected. The benefit of using refrigerant leak sensors is to prevent leaks from occurring and to ensure that the refrigeration system is operating efficiently, as refrigerant leaks can cause the system to lose efficiency and potentially cause equipment damage.